JCB Machine Fault Identification


mk:@MSITStore:C:JCB_Servicemaster_2ExtrasAccessK300_ToolsK

This section contains a summary of the errors that can occur when charging the battery.

Fault Identification

When a fault occurs, LED2 (100%), LED3 (75%) and LED4 (50%), shown in Figure 1, will blink at the same time.

Figure 1.

Blinking Frequency

Fault Cause

Solution

1

The battery is not connected or the battery voltage is too low

Ensure battery is connected.

Do not charge the battery if the voltage is less than 4V.

2

Abnormal AC power input (Voltage)

Check AC input cord is connected between charger and AC outlet.

Make sure AC plug is tightly secured into the AC outlet.

3

Charger High Temperature Protection

The charger will shut down and go into protection mode. Please place the charger into an area with ambient air flow or a cooler place.

4

Battery High Temperature Protection

The charger will reduce or even stop charging when the battery temperature exceeds 50°C.

Disconnect the charger and wait 15-20 minutes before reconnecting.

5

Output Current is too large

Return to the factory for repair.

6

Battery Voltage is too high (>28.5V)

Check and assure that the correct output battery voltage is connected.

7

Battery Voltage is too low (<17.5V)

Check and assure that the correct output battery voltage is connected.

This topic last edited on 09/08/2017