ADVERTICEMENT
Sensor Supply 2 Circuit - Voltage Below Normal or Shorted to Low Source. Low voltage detected at the sensor supply 2 circuit.
FAULT CODE 187
Sensor Supply 2 Circuit - Voltage Below Normal or Shorted to Low Source
Overview
CODE | REASON | EFFECT |
Fault Code: 187 | Sensor Supply 2 Circuit - Voltage Below Normal or Shorted to Low Source. Low voltage | Loss of some sensor |
PID: | detected at the sensor supply 2 circuit. | functionality. |
SPN: 3510 | ||
FMI: 4/4 | ||
LAMP: Amber | ||
SRT: |
Sensor Supply 2 Circuit - Industrial Engines
Sensor Supply 2 Circuit - Power Generation Engin
Sensor Supply 2 Circuit - Marine Engines
Circuit Description
The sensor supply 2 circuit of the engine control module (ECM) provides 5-VDC for the engine camshaft speed/position sensor, intake manifold 1 pressure sensor, fuel delivery pressure sensor, barometric pressure sensor, and injector metering rail 1 pressure sensor.
Component Location
The sensor supply 2 is located in the ECM.
Use the following procedure for a detailed component location view. Refer to Procedure 100-002 in Section E.
Shop Talk
Low voltage on the 5-VDC supply wire can be caused by a short circuit to ground in a supply wire, a short circuit between a supply wire or a return wire, a damaged sensor, or a damaged ECM power supply.
Refer to Troubleshooting Fault Code t05-187.
Last Modified: 28-Nov-2012