CUMMINS FAULT CODE 187

ADVERTICEMENT

Sensor Supply 2 Circuit - Voltage Below Normal or Shorted to Low Source. Low voltage detected at the sensor supply 2 circuit.

mk:@MSITStore:C:\Users\HP\Desktop\Backup\Insite\Cummins%20FIS\F


FAULT CODE 187

Sensor Supply 2 Circuit - Voltage Below Normal or Shorted to Low Source

Overview


CODE

REASON

EFFECT

Fault Code: 187

Sensor Supply 2 Circuit - Voltage Below Normal or Shorted to Low Source. Low voltage

Loss of some sensor

PID:

detected at the sensor supply 2 circuit.

functionality.

SPN: 3510



FMI: 4/4



LAMP: Amber



SRT:



Sensor Supply 2 Circuit - Industrial Engines


Sensor Supply 2 Circuit - Power Generation Engin


Sensor Supply 2 Circuit - Marine Engines


Circuit Description

The sensor supply 2 circuit of the engine control module (ECM) provides 5-VDC for the engine camshaft speed/position sensor, intake manifold 1 pressure sensor, fuel delivery pressure sensor, barometric pressure sensor, and injector metering rail 1 pressure sensor.


Component Location


The sensor supply 2 is located in the ECM.


Use the following procedure for a detailed component location view. Refer to Procedure 100-002 in Section E.


Shop Talk


Low voltage on the 5-VDC supply wire can be caused by a short circuit to ground in a supply wire, a short circuit between a supply wire or a return wire, a damaged sensor, or a damaged ECM power supply.


Refer to Troubleshooting Fault Code t05-187.