FAULT CODE 115 - Engine Magnetic Speed/Position Lost Both of Two Signals - Data Erratic, Intermittent, or Incorrect
Associated Procedures Troubleshooting Steps
STEPS | SPECIFICATIONS |
STEP 1. Check the fault codes. STEP 1A. Determine if Fault Code Fault Code 115 becomes active during 115 becomes active during cranking? cranking. STEP 1B. Inspect the engine Harness connectors connected to harness. correct sensors? STEP 2. Clear the fault codes. STEP 2A. Disable the fault code. Fault Code 115 inactive? STEP 2B. Clear the inactive fault All fault codes cleared? codes. |
Guided Step 1 - Check the fault codes.
Guided Step 1A - Determine if Fault Code 115 becomes active during cranking. |
Conditions
|
Fault Code 115 becomes active during cranking? | |
YES | NO |
No Repair | No Repair |
Go to 1B | Go to 2A |
Guided Step 1B - Inspect the engine harness. | |
Conditions
| |
Harness connectors connected to correct sensors? | |
YES | NO |
No Repair | No Repair |
Go to 2A | Go to 2A |
Guided Step 2 - Clear the fault codes
Guided Step 2A - Disable the fault code. | |
Conditions
| |
Fault Code 115 inactive? | |
YES | NO |
Return to the troubleshooting steps or contact |
No Repair | a local Cummins® Authorized Repair location if all steps have been completed and checked again. |
Go to 2B | Go to 1A |
Guided Step 2B - Clear the inactive fault codes. | |
Conditions
| |
All fault codes cleared? | |
YES | NO |
No Repair | No Repair |
Repair complete | Appropriate troubleshooting steps |
Last Modified: 28-Nov-2012