CUMMINS FAULT CODE 197

ADVERTICEMENT


cummins insite keygen



mk:@MSITStore:C:UsersHPDesktopBackupInsiteCummins%20FISF

FAULT CODE 197

Coolant Level – Data Valid But Below Normal Operating Range – Moderately Severe Level

Overview

CODE

REASON

EFFECT

Fault Code: 197

Coolant Level – Data Valid But Below Normal Operating Range – Moderately Severe Level. Low

None on

PID:

engine coolant level detected.

performance.

SPN: 111

FMI: 1/18

LAMP: Amber

SRT:

Coolant Level Sensor 1 Circuit – Industrial Engine

Coolant Level Sensor 1 Circuit – Marine Engines

Coolant Level Sensor 1 Circuit – Power Generation En

Circuit Description

The engine control module (ECM) supplies a 5-volt supply to the engine coolant level sensor using a common sensor supply circuit. The ECM also provides a ground on the sensor return circuit. The coolant level sensor 1 monitors the engine coolant level within the coolant system and passes information to the ECM through the original equipment manufacturer (OEM) harness and engine harness.

Component Location

The coolant level sensor 1 is typically located in the radiator top tank or surge tank. Refer to the OEM service manual for location.

Shop Talk

Some engines are equipped with a 2-wire sensor instead of a 3-wire sensor. The 2-wire sensors do not have the 5-volt supply wire in the circuit. Possible causes of this fault code include:

  • Open return or signal circuit in the harness, connectors, or sensor

  • Signal wire shorted to sensor supply or battery voltage

  • An open supply circuit in the harness (on 3-wire sensors only).

Refer to Troubleshooting Fault Code t05-197.